Temperature Assemblies
> Magnetic Mounted RTD
44.jpg
  • Magnet Mount Thermocouplescan be utilised on any ferrousmetals as an easy means tomeasure surface temperature ofan object                                                    

  • Provide a portable means ofsurface measurement that takesthe hassle out of mounting asurface probe to a metal object

 

43.jpg
> Conduit Style
  • Armoured cable protects the leads ofthermocouples types E, J, K, N & T

  • Well suited for industrial environments whereunprotected probes may be cut or broken

  • Metal sheaths made to your required length

> Bearing RTD
42.jpg
  • High precision RTDs for fast, stable, repeatablemeasurements where there are space limitations

  • RTD sensor Pt100 Class, B, A, AA, 1/10 DIN

  • Measuring range of -200℃ to +260℃

  • Field bendable

  • Moisture proof and oil seepage proof

41.jpg
> High Temperature Probes
  • Series ITCL & ITPG

  • Thermocouple probes type R, S and B.

  • Measuring range up to 1700°C.

40.jpg
> Miniature Embedded Probes
  • Small, rugged RTDs towithstand rough handling andharsh environments

  • Sensor Pt100 Class AA, A, B

  • Measuring range from-50℃ to +260℃

> Bayonet Mount Probes
39.jpg
  • Easy and inexpensive spring loaded installationof probes in solids

  • Lock cap and spring for twist-and-release springloading

  • Thermocouple or RTD probes options

  • Accurate sensing from -50℃ to +260℃

38.jpg
> Spring Loaded Probes
  • Spring loaded, tip sensitive RTD andthermocouple probes

  • Sensor PT100 class A, B, AA, 1/5, 1/10 DIN.Thermocouple inputs type K, J, T and N.

  • Measuring range dependant on sensor selectionminimum -200℃ to +1200℃

  • Insulated or bonded junction hot end and aselection of cold end seals and terminal blocks tosuit application

> Fast Response Probes
37.jpg
  • Fast response probe with low mass element toreact quickly to temperature changes

  • Sensor PT100 class A, B, AA, 1/5, 1/10 DIN.Thermocouple inputs type K, J, T and N.

  • Measuring range dependant on sensor selectionminimum -200℃ to +1200℃

> General Purpose Probes
37.jpg
  • RTD probes for stable, repeatable measurementsand excellent performance in high levels ofshock/vibration - Sensor PT100 class A, B, AA,1/5, 1/10 DIN

  • Thermocouple probes for wider temperatureranges - sensor inputs type K, J, T and N

  • Field bendable, Inconel or stainless steel sheath

  • Measuring range minimum -200℃ to +1200℃

> General Purpose
48.jpg
  • Standard assemblies fitted with available MIprobes (specified in Probe Section)

  • Numerous connection head and transmitteroptions available

  • Options for explosion proof and flameproof ratingfor hazardous areas

  • RTD or Thermocouple assemblies - Sensor PT100 class, A, B, AA, 1/5, 1/10 DIN

  • Thermocouple inputs type K, J, T, and N

  • Measuring range dependant on senor selection:-200℃ to +1200℃

> Pipe Clamp
45.jpg
  • Easily fitted to pipe - No need for thermowell inpipe

  • Accuracy and response is similar to immersedthermowell assembly

  • Numerous connection head and transmitteroptions available

  • Options for explosion proof and flameproof ratingfor hazardous areas

  • RTD or Thermocouple sensors available

  • Sensor PT100 class A, B, AA, 1/5, 1/10 DIN

  • Thermocouple inputs type K, J, T and N

  • Measuring range dependant on sensor: -200℃to +300℃

> High Temperature Ceramic
49.jpg
  • High temperature ceramic assemblies

  • Measuring range up to +1700℃

  • Options for explosion proof or flame proof ratingfor hazardous areas

> Standard Assembly
48.jpg
  • Standard assemblies fitted with available MIprobes (specified in Probe Section)

  • Numerous connection head & transmitteroptions available

  • Options for explosion proof and flameproofrating for hazardous areas

  • RTD or Thermocouple assemblies - Sensor PT100 class, A, B, AA, 1/5, 1/10 DINThermocouple inputs type K, J, T, and N

  • Measuring range dependant on sensorselection: -200OC to +1200OC

52.jpg
> Velocity Collar
  • Range of solid drilledthermowells constructed withthe addition of a velocity collarwhich is a metal ring machinedonto profile of thermowell

  • Reduces the unsupportedlength of the thermowell

  • Reduces vibration

> Fabricated
51.jpg
  • Fabricated thermowellsmanufactured from pipe, tubeor bar which are then sealed bya solid welded tip

  • Low cost alternative to soliddrilled construction whenhigh pressure not a designconsideration

  • Wide Range of Materials

  • Choice of process connections

  • ASME IX Coded Welding

  • Special Coatings

  • Non Destructive Testing

> Solid Drilled
50.jpg
  • Drilled from solid bar forprocess pressure

  • Wide Range of Materialsincluding Stainless Steels andexotic materials

  • Parallel or tapered stems

  • Flat, domed or round tips

  • Choice of ProcessConnections: Flanged,Screwed, Weld-In

  • One piece Forgings

  • ASME IX Coded Welding

  • Special Coatings

  • Non Destructive Testing

121.jpg
> TC-RTD Transmitter
  • Pt100 type: 2, 3 Wire

  • Thermocouple type: K, J, N, E, T, R, S

  • Potentiometer input (1 to 100) kΩ auto sense

  • Power supply (10 to 30) VDC, Voltage (-10 to 75) mV, Output (4 to 20) mA

  • Isolation

  • Ambient Operation (-40 to +85) deg C

  • Diameter 43 mm

  • Sine Vibration DNV Standard

> Hart Protocol Transmitter
122.jpg
  • Pt100 type: 2, 3 & 4 Wire

  • Thermocouple type: K, J, T, R, S, E, L, N, Custom

  • Potentiometer input up to 100kΩ with external resistor

  • Power supply (10 to 40) VDC, Output (4 to 20) mA HART, Voltage (-10 to 75) mV

  • Ambient Operation (-40 to +85) deg C

  • Sine Vibration DNV Standard

  • Diameter 44 mm

  • Custom linearisation

> Programmable Tx
59.jpg
  • Pt100 type: 2, 3 Wire

  • Thermocouple type: K, J, N, E, T, R, S

  • Potentiometer input (1 to 100) kΩ auto sense

  • Power supply (10 to 30) VDC, Voltage (-10 to 75) mV, Output (4 to 20) mA

  • Isolation

  • Ambient Operation (-40 to +85) deg C

  • Diameter 43 mm

  • Sine Vibration DNV Standard

58.jpg
> Fixed Range Transmitter
  • Manufactured to a high specification

  • Fixed range for RTDs, Thermocouples,Resistance - sensor, mV

  • Easily adjustable zero and span potentiometers

  • Analogue output 4 ... 20mA, invertible, 2 - wiredesign

  • 7T48: ATEX Approved, EExia (fixed in H70Head), Thermocouple and RTD Inputs

> Thermocouple Transmitter
120.jpg
  • Thermocouple type: K, J, N, E, T, R, S

  • Voltage (-10 to 70) mVDC, Output (4 to 20) mA

  • PC Configuration

  • Isolation

  • Ambient Operation (-40 to +85) deg C

  • Power supply (10 to 30) VDC

  • Diameter 43 mm

  • Sine Vibration DNV Standard

119.jpg
> Pt100 Transmitter
  • Pt100 type: 2, 3 Wire

  • Output (4 to 20) mA

  • No Isolation

  • Ambient Operation (-40 to +85) deg C

  • Power supply (10 to 30) VDC

  • PC Configuration

  • Diameter 43 mm

  • Sine Vibration DNV Standard

bottom of page